Villamosszigetelő és Műanyaggyár Kft.

Products...

  • 1
  • 2
  • 3
  • 4
Prev Next

PE-RT Wall and under-floor hea…

Hot water and heating pipes

PE-RT Wall and under-floor heating pipe

Standard: DIN 16833 : 2001, DIN 16834 : 2001, DIN 4726 : 2000 Number of ...

Supporting insulators with a n…

Supporting, crossover and connecting insulator

Supporting insulators with a nominal working voltage over 1kV

Types: ETA 12, ETB 12, ETC 12, ETB 24-1, ETB 24-2, ETB 40, ETC 40 Standard:&nb...

Plastic bent pipe for MÜ I. pi…

Isulated pipes

Plastic bent pipe for MÜ I. pipes

Type: MÜ I. Standard: VSZM TS 06.32/2001 Application field: For joining MÜ...

MüV type of rigid protecting p…

Isulated pipes

MüV type of rigid protecting pipes for electrical use

Types: MüV I. MüV II. Application: The MÜV type of protecting pipe is applica...

Pipe for cold and hot water ne…

Hot water and heating pipes

Pipe for cold and hot water network, central-heating and under-floor heating systems

Standard: EN ISO 15875 – 1: 2003, EN ISO 15875 – 2: 2003, DIN 4726 :2000, DIN ...

Isonal 2000® plastic cable tru…

Channels

Isonal 2000® plastic cable trunking system

Introduction and application: Building electrical, telecommunication and recently i...

MÜ I - Thick walled rigid plas…

Isulated pipes

MÜ I - Thick walled rigid plastic pipes

Type: MÜ I., Standard: VSZM TS 06.30/2001. (MSZ EN 61386 except dimensio...

MCSE Plastic cable channel

Channels

MCSE Plastic cable channel

Type: MCSE 1, MCSE 2, MCSE 3 Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:...

Crossover insulators 12, 24 kV

Types: ASM 12/8, ASM 12/16, ASM 12/30, ASM 24
Standard: VSZM VSZ 50-86

Application field: At voltage levels of 12 kV, 24 kV for indoor application. It assures the necessary electric insulation for conductors through walls or other structural parts.

Material: Epoxy resin filled with silica-flour – indoor application

According to requirements we can produce crossover insulators made of cyclo-alyphatic epoxy casting resin system for outdoor application as well. Crossover insulators for outdoor application are unpainted or they can be coloured according to agreements

Colour: Indoor application: Red

  Outdoor application: Not painted

Dimensions and shaping:

Typical technical data (Description)

 

ASM 12/8

ASM 12/16

ASM 12/30

ASM 24

Product number

-

ÖF 4276

ÖF 4321

ÖF 4322

ÖF 4323

Nominal voltage

kV

12

12

12

24

Nominal electric current

A

800

1600

3000

1200

Nominal thermic limiting current

kA

20

40

75

30

Nominal thermic limiting time

-

1 sec.

1 sec.

1 sec.

1 sec.

Nominal dynamic limiting current

kA

50

100

187,5

75

Test voltage at industrial frequency

kV/1'

35

35

35

55

Impulse test voltage

kV

75

75

75

125

Sizes:

inner (d/1)

mm

90

110

140

80

enlarged with ribs (d/2)

mm

110

130

160

120

the biggest (d/3)

mm

135

155

185

170

length

mm

272

272

272

490

Sectional sizes/numbers of the contact rails (see the fig. No.4.) can be passed through the armature of the crossover insulator

mm x mm /pc

40x10/1

80x10/1

100x10/2

60x10/1

   

60x10/1

80x10/2

100x10/3

60x10/2

VEIKI standard inspection report number

-

746/VBF

746/VBF

-

748/VBF

             

Products have been tested and approved by VEIKI (Hungarian Institute for Research of Electric Power Industry).

Execution: In cartons

 

Last modified onSaturday, 24 June 2017 11:00