Villamosszigetelő és Műanyaggyár Kft.

Products...

  • 1
  • 2
  • 3
  • 4
Prev Next

Connecting insulator

Supporting, crossover and connecting insulator

Connecting insulator

Type: KT – 4 – 125 Standard: VSZM TS 05.3 / 99 Appli...

MCS Plastic cable channel

Channels

MCS Plastic cable channel

Type: MCS Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:1998, CEI IEC 1084-1...

Guide post to show the edge of…

Profiles and other products

Guide post to show the edge of public road

Standard: MSZ -07-3609:1981  Area of use: to show the track and edge...

Isonal 2000® plastic cable tru…

Channels

Isonal 2000® plastic cable trunking system

Introduction and application: Building electrical, telecommunication and recently i...

KPE Pressure pipeline for port…

Hot water and heating pipes

KPE Pressure pipeline for portable water supply

Type:: KPE P6, P10 Standard: MSZ 7908/1 Application field: Pipes are applica...

MÜ I - Thick walled rigid plas…

Isulated pipes

MÜ I - Thick walled rigid plastic pipes

Type: MÜ I., Standard: VSZM TS 06.30/2001. (MSZ EN 61386 except dimensio...

Plastic sleeve for MÜV protect…

Isulated pipes

Plastic sleeve for MÜV protecting pipes

Type: MÜV k. Standard: MSZEN 50086-1:1997; MSZEN 61386-21:2008 App...

Plastic bent pipe for MÜ I. pi…

Isulated pipes

Plastic bent pipe for MÜ I. pipes

Type: MÜ I. Standard: VSZM TS 06.32/2001 Application field: For joining MÜ...

MCS Plastic cable channel

Type: MCS

Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:1998, CEI IEC 1084-1:1991-6,CEI IEC 1084-1-1:1993-10

Applicable fields: Applicable according to the Construction Standard No.: MSZ 2364 to protect insulated electric cables from high mechanical stress in such wooden construction, where electric circuital cables cannot be build in either at the prefabrication nor afterwards.

Useful: First of all they are useful in industrial buildings, but in living houses, office buildings as well, where rooms are dry, not corrosive vaporous and dusty, classified in inflammable risk for at most “D”. Cable channels are useful between -5 and +60 °C protect from direct sunshine. They are not suitable for protection from spurting water. Cable channel consists of a bottom and a cover. The junction of the two parts is made possible by the flexibility of the material and by the suitable shaping of the parts. Advantage of this type against the other models, that after junction the bottom and the cover are co-planar, so you can put more channels tightly next to each other. The cover can be removed without any tools. Location of the channel can be vertical or horizontal.

Material: rigid PVC for electrical use

Colour: white or according to customer’s requirements

Dimension:

Description

Part of the channel

Label No.

Dimension of the channel

height x width

   

A

B

C

mm

   

mm

mm

mm

           

15x12 koax

cover

6195

13,6

12,5

1

 

bottom

6196

4,5

12

1

MCS 15x15

cover

6229

13

15

1

 

bottom

6230

5

15

1

MCS 25x25

cover

5660

8

25

1,5

X

bottom

5657

23

25

1,6

MCS 25x50

cover

5664

8

50

1,5

X

bottom

5661

23

50

1,6

MCS 25x100

cover

5616

8

100

1,5

X

bottom

5665

23

100

2,0

MCS 32x25

cover

5660

8

25

1,5

X

bottom

5658

30

25

1,6

MCS 32x50

cover

5664

8

50

1,5

X

bottom

5662

30

50

1,6

MCS 32x100

cover

5616

8

100

1,5

X

bottom

5666

30

100

1,8

MCS 40x40

cover

6176

8

40

1,4

X

bottom

6175

38

40

2,0

MCS 40x60

cover

6178

8

60

1,4

X

bottom

6177

38

60

2,0

MCS 40x80

cover

6180

8

80

1,4

X

bottom

6179

38

80

2,0

MCS 50x25

cover

5660

8

25

1,6

X

bottom

5659

48

25

1,8

MCS 50x50

cover

5664

8

50

1,5

X

bottom

5663

48

50

2,0

MCS 50x100

cover

5616

8

100

1,5

X

bottom

5615

48

100

2,0

Execution: Types marked with X are available also with perforated side wall according to picture 3. (perforated cable channels)

Picture No.1.

Picture No.2.

Picture No.3.

cover

bottom

perforated wall

Execution: in 2 metres long bundles, the size of 25x25 is bundled in 25 pc/bd, 25x50, 50x50 are bundled in 12 pc/bd, 50x100 is bundled in 6 pc/bd, bottom and cover are compact.

Material: rigid PVC for electrical use

Material properties:

Density

gr/cm3

1,6

Tensile strength

MPa

min 40

Elongation at break

%

min 10

Impact-bending strength (Charpy)

KJ/m2

3,5

Breakdown voltage

kV/mm

min 20

Specific volumetric resistance

Ohm

min 1012

Strength properties:

Mechanical capacity

Type

Maximal capacity (with cable)

15x12 koax

0,16 kg/m

MCS 15x15

0,20 kg/m

MCS 25x25

0,56 kg/m

MCS 32x25

0,74 kg/m

MCS 50x25

1,22 kg/m

MCS 25x50

1,25 kg/m

MCS 32x50

1,66 kg/m

MCS 50x50

2,72 kg/m

MCS 25x100

2,63 kg/m

MCS 32x100

3,49 kg/m

MCS 50x100

5,73 kg/m

MCS 40x40

1,77 kg/m

MCS 40x60

2,67 kg/m

MCS 40x80

3,75 kg/m

Impact resistance: After a reheating treatment at 60 ± 2 °C for 240 hours and then at -5 °C for 2 hours it will not break under effect of impact energy of 2 J.

Thermal properties:

Storing, constructing and applicable range of temperature is between -5 °C - and +60 °C

Flame proofing: it does not spread the flame, after removing the ignition flame it will be extinguished.

Electrical properties:

Electric conductivity: product does not ensure constant conductivity.

Electrical insulation: product has electrical insulation property: IP30

Protection from incursion of external effects: IP3X (

Protection against water incursion: IPX0

Parts of cables under electric tension in the channel (in joined position) cannot be touched.

Protection from corrosion and pollutant materials: Strong outer protection, weak inner protection.

Joining of the cover: The cover can be removed without any instruments

Adequacy statement of production:

Straight execution: "CE"- applicable: 6/98 VSZM Kft. according to government decree No. 208/1999 XII.29. and 79/1997 IKIM

Perforated execution: “CE"- applicable: 7/98 VSZM Kft. according to government decree No. 208/1999 XII.29. and 79/1997 IKIM