MÜ III - Thin-walled flexible …

Isulated pipes

MÜ III - Thin-walled flexible plastic pipes

Type: MÜ III. Standard: VSZMTS 06.30/2001. (MSZEN 61386 except dimension...

Crossover insulators 12, 24 kV

Supporting, crossover and connecting insulator

Crossover insulators 12, 24 kV

Types: ASM 12/8, ASM 12/16, ASM 12/30, ASM 24 Standard: VSZM VSZ 50-86...

HDPE Protective pipe for cable…

Profiles and other products

HDPE Protective pipe for cables

Standard: MSZ EN 50086 – 1, MSZ EN 50086 – 2 – 4, IEC 614, MATÁV – PKI – FI MMD 23...

Plastic bent pipe for MÜV pipe…

Isulated pipes

Plastic bent pipe for MÜV pipes

Type: MÜV kö. Standard: MSZEN 50086-1:1997; MSZEN 61386-21:2008 Ap...

Plastic sleeve for MÜV protect…

Isulated pipes

Plastic sleeve for MÜV protecting pipes

Type: MÜV k. Standard: MSZEN 50086-1:1997; MSZEN 61386-21:2008 App...

Plastic Profiles

Profiles and other products

Plastic Profiles

Application field: Extruded plastic profiles are developed for the building- and f...

MCS Plastic cable channel

Channels

MCS Plastic cable channel

Type: MCS Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:1998, CEI IEC 1084-1...

PE-RT Wall and under-floor hea…

Hot water and heating pipes

PE-RT Wall and under-floor heating pipe

Standard: DIN 16833 : 2001, DIN 16834 : 2001, DIN 4726 : 2000 Number of ...

Plastic bent pipe for MÜ I. pipes

Type: MÜ I.

StandardVSZM TS 06.32/2001

Application field: For joining MÜ I. rigid thick-walled protecting pipes, in determined environments and conditions.

Material: Rigid PVC for electrical use

Colour: brown or grey

Sizes:

Description and nominated sizes of plastic bent pipes:

Description

D (mm)

v min

R (mm)

a (mm)

         

MÜ I.kö.

       

11

18,4 (+/- 0,15)

1,3

85

60 +/-3

13,5

20,4 (+/-0,15)

1,4

85

60 +/-3

16

22,5 (+/- 0,15)

1,5

85

60 +/-3

21

28,3 (+/- 0,15)

1,65

85

60 +/-3

29

37,0 (+/- 0,20)

1,8

141

90 +/-5

36

47,0 (+/- 0,20)

2,1

141

90 +/-5

48

54,0 (+/- 0,25)

2,2

141

90 +/-5

Execution: according to requirements of customers.

Raw material:

Density

g/cm3

1,65

Tensile strength

MPa

40

Elongation at break

%

15

Specific volumetric resistance at 20 °C

Ohm x cm

1 x 1015

Breakdown voltage

kV/mm

20

Strength properties:

Impact resistance: After a reheating treatment at 60 ± 2 °C for 240 hours and then at -5 °C for 2 hours it will not break under effect of impact energy of 2 J.

Heat-resistance: 60 ±2 °C according to VSZM TS 06.30/2001

Ignitability: tubes are hardly inflammable according to V0 and self extinguish

Electrical properties:

Electric strength: Tubes comply with requirements in case of test at 2000 V during 15 min. after immersion in water during 24 hours.

Insulation resistances: min. 100 MOhm