Type: MCS
Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:1998, CEI IEC 1084-1:1991-6,CEI IEC 1084-1-1:1993-10
Applicable fields: Applicable according to the Construction Standard No.: MSZ 2364 to protect insulated electric cables from high mechanical stress in such wooden construction, where electric circuital cables cannot be build in either at the prefabrication nor afterwards.
Useful: First of all they are useful in industrial buildings, but in living houses, office buildings as well, where rooms are dry, not corrosive vaporous and dusty, classified in inflammable risk for at most “D”. Cable channels are useful between -5 and +60 °C protect from direct sunshine. They are not suitable for protection from spurting water. Cable channel consists of a bottom and a cover. The junction of the two parts is made possible by the flexibility of the material and by the suitable shaping of the parts. Advantage of this type against the other models, that after junction the bottom and the cover are co-planar, so you can put more channels tightly next to each other. The cover can be removed without any tools. Location of the channel can be vertical or horizontal.
Material: rigid PVC for electrical use
Colour: white or according to customer’s requirements
Dimension:
Description |
Part of the channel |
Label No. |
Dimension of the channel |
||
height x width |
A |
B |
C |
||
mm |
mm |
mm |
mm |
||
15×12 koax |
cover |
6195 |
13,6 |
12,5 |
1 |
bottom |
6196 |
4,5 |
12 |
1 |
|
MCS 15×15 |
cover |
6229 |
13 |
15 |
1 |
bottom |
6230 |
5 |
15 |
1 |
|
MCS 25×25 |
cover |
5660 |
8 |
25 |
1,5 |
X |
bottom |
5657 |
23 |
25 |
1,6 |
MCS 25×50 |
cover |
5664 |
8 |
50 |
1,5 |
X |
bottom |
5661 |
23 |
50 |
1,6 |
MCS 25×100 |
cover |
5616 |
8 |
100 |
1,5 |
X |
bottom |
5665 |
23 |
100 |
2,0 |
MCS 32×25 |
cover |
5660 |
8 |
25 |
1,5 |
X |
bottom |
5658 |
30 |
25 |
1,6 |
MCS 32×50 |
cover |
5664 |
8 |
50 |
1,5 |
X |
bottom |
5662 |
30 |
50 |
1,6 |
MCS 32×100 |
cover |
5616 |
8 |
100 |
1,5 |
X |
bottom |
5666 |
30 |
100 |
1,8 |
MCS 40×40 |
cover |
6176 |
8 |
40 |
1,4 |
X |
bottom |
6175 |
38 |
40 |
2,0 |
MCS 40×60 |
cover |
6178 |
8 |
60 |
1,4 |
X |
bottom |
6177 |
38 |
60 |
2,0 |
MCS 40×80 |
cover |
6180 |
8 |
80 |
1,4 |
X |
bottom |
6179 |
38 |
80 |
2,0 |
MCS 50×25 |
cover |
5660 |
8 |
25 |
1,6 |
X |
bottom |
5659 |
48 |
25 |
1,8 |
MCS 50×50 |
cover |
5664 |
8 |
50 |
1,5 |
X |
bottom |
5663 |
48 |
50 |
2,0 |
MCS 50×100 |
cover |
5616 |
8 |
100 |
1,5 |
X |
bottom |
5615 |
48 |
100 |
2,0 |
Execution: Types marked with X are available also with perforated side wall according to picture 3. (perforated cable channels)
Execution: in 2 metres long bundles, the size of 25×25 is bundled in 25 pc/bd, 25×50, 50×50 are bundled in 12 pc/bd, 50×100 is bundled in 6 pc/bd, bottom and cover are compact.
Material: rigid PVC for electrical use
Material properties:
Density | gr/cm3 | 1,6 |
Tensile strength | MPa | min 40 |
Elongation at break | % | min 10 |
Impact-bending strength (Charpy) | KJ/m2 | 3,5 |
Breakdown voltage | kV/mm | min 20 |
Specific volumetric resistance | Ohm | min 1012 |
Strength properties:
Mechanical capacity
Type | Maximal capacity (with cable) |
15×12 koax | 0,16 kg/m |
MCS 15×15 | 0,20 kg/m |
MCS 25×25 | 0,56 kg/m |
MCS 32×25 | 0,74 kg/m |
MCS 50×25 | 1,22 kg/m |
MCS 25×50 | 1,25 kg/m |
MCS 32×50 | 1,66 kg/m |
MCS 50×50 | 2,72 kg/m |
MCS 25×100 | 2,63 kg/m |
MCS 32×100 | 3,49 kg/m |
MCS 50×100 | 5,73 kg/m |
MCS 40×40 | 1,77 kg/m |
MCS 40×60 | 2,67 kg/m |
MCS 40×80 | 3,75 kg/m |
Impact resistance: After a reheating treatment at 60 ± 2 °C for 240 hours and then at -5 °C for 2 hours it will not break under effect of impact energy of 2 J.
Thermal properties:
Storing, constructing and applicable range of temperature is between -5 °C – and +60 °C
Flame proofing: it does not spread the flame, after removing the ignition flame it will be extinguished.
Electrical properties:
Electric conductivity: product does not ensure constant conductivity.
Electrical insulation: product has electrical insulation property: IP30
Protection from incursion of external effects: IP3X (
Protection against water incursion: IPX0
Parts of cables under electric tension in the channel (in joined position) cannot be touched.
Protection from corrosion and pollutant materials: Strong outer protection, weak inner protection.
Joining of the cover: The cover can be removed without any instruments
Adequacy statement of production:
Straight execution: “CE”- applicable: 6/98 VSZM Kft. according to government decree No. 208/1999 XII.29. and 79/1997 IKIM
Perforated execution: “CE”- applicable: 7/98 VSZM Kft. according to government decree No. 208/1999 XII.29. and 79/1997 IKIM