Villamosszigetelő és Műanyaggyár Kft.

Products...

  • 1
  • 2
  • 3
  • 4
Prev Next

Plastic Profiles

Profiles and other products

Plastic Profiles

Application field: Extruded plastic profiles are developed for the building- and f...

Plastic bent pipe for MÜ I. pi…

Isulated pipes

Plastic bent pipe for MÜ I. pipes

Type: MÜ I. Standard: VSZM TS 06.32/2001 Application field: For joining MÜ...

HDPE Protective pipe for cable…

Profiles and other products

HDPE Protective pipe for cables

Standard: MSZ EN 50086 – 1, MSZ EN 50086 – 2 – 4, IEC 614, MATÁV – PKI – FI MMD 23...

MüV type of rigid protecting p…

Isulated pipes

MüV type of rigid protecting pipes for electrical use

Types: MüV I. MüV II. Application: The MÜV type of protecting pipe is applica...

PP-R Wall and under-floor heat…

Hot water and heating pipes

PP-R Wall and under-floor heating pipe

Standard: MSZ EN ISO 15874 – 1: 2004, MSZ EN ISO 15874 – 2: 2004, DIN 4726 :2000 ...

KPE Pressure pipeline for port…

Hot water and heating pipes

KPE Pressure pipeline for portable water supply

Type:: KPE P6, P10 Standard: MSZ 7908/1 Application field: Pipes are applica...

Pipe for cold and hot water ne…

Hot water and heating pipes

Pipe for cold and hot water network, central-heating and under-floor heating systems

Standard: EN ISO 15875 – 1: 2003, EN ISO 15875 – 2: 2003, DIN 4726 :2000, DIN ...

Plastic bent pipe for MÜV pipe…

Isulated pipes

Plastic bent pipe for MÜV pipes

Type: MÜV kö. Standard: MSZEN 50086-1:1997; MSZEN 61386-21:2008 Ap...

Products

Products (21)

The left side menu you can select an interesting product, so the

  • pipes
  • channels
  • profiles

get detailed information about our products or tabular summary

MCS Plastic cable channel

Type: MCS

Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:1998, CEI IEC 1084-1:1991-6,CEI IEC 1084-1-1:1993-10

Applicable fields: Applicable according to the Construction Standard No.: MSZ 2364 to protect insulated electric cables from high mechanical stress in such wooden construction, where electric circuital cables cannot be build in either at the prefabrication nor afterwards.

Useful: First of all they are useful in industrial buildings, but in living houses, office buildings as well, where rooms are dry, not corrosive vaporous and dusty, classified in inflammable risk for at most “D”. Cable channels are useful between -5 and +60 °C protect from direct sunshine. They are not suitable for protection from spurting water. Cable channel consists of a bottom and a cover. The junction of the two parts is made possible by the flexibility of the material and by the suitable shaping of the parts. Advantage of this type against the other models, that after junction the bottom and the cover are co-planar, so you can put more channels tightly next to each other. The cover can be removed without any tools. Location of the channel can be vertical or horizontal.

Material: rigid PVC for electrical use

Colour: white or according to customer’s requirements

Dimension:

Description

Part of the channel

Label No.

Dimension of the channel

height x width

   

A

B

C

mm

   

mm

mm

mm

           

15x12 koax

cover

6195

13,6

12,5

1

 

bottom

6196

4,5

12

1

MCS 15x15

cover

6229

13

15

1

 

bottom

6230

5

15

1

MCS 25x25

cover

5660

8

25

1,5

X

bottom

5657

23

25

1,6

MCS 25x50

cover

5664

8

50

1,5

X

bottom

5661

23

50

1,6

MCS 25x100

cover

5616

8

100

1,5

X

bottom

5665

23

100

2,0

MCS 32x25

cover

5660

8

25

1,5

X

bottom

5658

30

25

1,6

MCS 32x50

cover

5664

8

50

1,5

X

bottom

5662

30

50

1,6

MCS 32x100

cover

5616

8

100

1,5

X

bottom

5666

30

100

1,8

MCS 40x40

cover

6176

8

40

1,4

X

bottom

6175

38

40

2,0

MCS 40x60

cover

6178

8

60

1,4

X

bottom

6177

38

60

2,0

MCS 40x80

cover

6180

8

80

1,4

X

bottom

6179

38

80

2,0

MCS 50x25

cover

5660

8

25

1,6

X

bottom

5659

48

25

1,8

MCS 50x50

cover

5664

8

50

1,5

X

bottom

5663

48

50

2,0

MCS 50x100

cover

5616

8

100

1,5

X

bottom

5615

48

100

2,0

Execution: Types marked with X are available also with perforated side wall according to picture 3. (perforated cable channels)

Picture No.1.

Picture No.2.

Picture No.3.

cover

bottom

perforated wall

Execution: in 2 metres long bundles, the size of 25x25 is bundled in 25 pc/bd, 25x50, 50x50 are bundled in 12 pc/bd, 50x100 is bundled in 6 pc/bd, bottom and cover are compact.

Material: rigid PVC for electrical use

Material properties:

Density

gr/cm3

1,6

Tensile strength

MPa

min 40

Elongation at break

%

min 10

Impact-bending strength (Charpy)

KJ/m2

3,5

Breakdown voltage

kV/mm

min 20

Specific volumetric resistance

Ohm

min 1012

Strength properties:

Mechanical capacity

Type

Maximal capacity (with cable)

15x12 koax

0,16 kg/m

MCS 15x15

0,20 kg/m

MCS 25x25

0,56 kg/m

MCS 32x25

0,74 kg/m

MCS 50x25

1,22 kg/m

MCS 25x50

1,25 kg/m

MCS 32x50

1,66 kg/m

MCS 50x50

2,72 kg/m

MCS 25x100

2,63 kg/m

MCS 32x100

3,49 kg/m

MCS 50x100

5,73 kg/m

MCS 40x40

1,77 kg/m

MCS 40x60

2,67 kg/m

MCS 40x80

3,75 kg/m

Impact resistance: After a reheating treatment at 60 ± 2 °C for 240 hours and then at -5 °C for 2 hours it will not break under effect of impact energy of 2 J.

Thermal properties:

Storing, constructing and applicable range of temperature is between -5 °C - and +60 °C

Flame proofing: it does not spread the flame, after removing the ignition flame it will be extinguished.

Electrical properties:

Electric conductivity: product does not ensure constant conductivity.

Electrical insulation: product has electrical insulation property: IP30

Protection from incursion of external effects: IP3X (

Protection against water incursion: IPX0

Parts of cables under electric tension in the channel (in joined position) cannot be touched.

Protection from corrosion and pollutant materials: Strong outer protection, weak inner protection.

Joining of the cover: The cover can be removed without any instruments

Adequacy statement of production:

Straight execution: "CE"- applicable: 6/98 VSZM Kft. according to government decree No. 208/1999 XII.29. and 79/1997 IKIM

Perforated execution: “CE"- applicable: 7/98 VSZM Kft. according to government decree No. 208/1999 XII.29. and 79/1997 IKIM

Read more...

MCSE Plastic cable channel

Type: MCSE 1, MCSE 2, MCSE 3

Standard: MSZ EN 50085-1:1998, MSZ EN 50085-2-1:1998,CEI IEC 1084-1:1991-6, CEI IEC 1084-1-1:1993-10

Application field: Applicable according to the Construction Standard No.: MSZ 1600 to protect insulated electric cables from high mechanical stress in such wooden construction, where electric circuital cables cannot be build in either at the prefabrication nor afterwards.

Useful: First of all they are useful in industrial buildings, but in living houses, office buildings as well, where rooms are dry, not corrosive vaporous and dusty, classified in inflammable risk for at most “D”. Cable channels are useful between -5 and +60 °C protect from direct sunshine. They are not suitable for protection from spurting water.

Cable channel consists of a bottom and a cover. The junction of the two parts is made possible by the flexibility of the material and by the suitable shaping of the parts. This channel has weather-proof quality, does not need colouring or maintenance.

The base part of the bottom of types MCSE 2 and MCSE 3 are perforated in every 150 mm to make easy the assembling.

A cable clamp is available for types of MCSE 2 and MCSE 3.

Material: rigid PVC for electrical use

Colour: white

Dimension:

Execution: in 2 metres long bundles, type of MCSE 1 is bundled 50 pc/bd, type of MCSE 2 is bundled in 25 pc/bd, type of MCSE 3 is bundled 10 pc/bd, bottom and cover are compact.

Raw material: Hard PVC – for electrical use

Density

g/cm3

1,6

Tensile strength

MPa

min.45

Elongation at break

%

min.20

Strength properties:

Mechanical capacity:

Type

Maximum capacity (with cables)

   

MCSE-1

0,09 kg/m

MCSE-2

0,35 kg/m

MCSE-3

0,74 kg/m

Impact resistance by assembling and application: the effect of impact energy of 0,5 J cause no breaks or cracks.

Thermal properties:

Storing, constructing and applicable range of temperature is between -5 °C - and +60 °C.

Flame proofing: It does not spread the flame

Electrical properties

It has electrical insulation property and it does not generate electrical conductivity.

Protection against external actions: IP30.

Resistance against penetration of solid objects: IP3X

Water-proofing: IPX0

Parts of cables under electric tension in the channel (in joined position) cannot be touched.

Protection against corrosive and pollutant materials: The material of the channel is corrosion-proof, but in inside there is no protection against corrosion.

Joining of the cover: The cover can be removed without any instruments

Adequacy statement of production: "CE"- applicable: 5/98 VSZM Kft. according to government decree No. 208/1999 and 79/1997 IKIM

 

Read more...

Isonal 2000® plastic cable trunking system

Introduction and application:

Building electrical, telecommunication and recently informatics networks outside walls has been a widely adopted practice for decades. The most important advantages of cable trunking are the easy accessibility, modification and extension. Flats and public buildings need a safe and elegant, aesthetical design and the recent construction technology, materials make possible to meet these requirements. Isonal 2000® system complies with the requirement of the unitary European technical prescriptions – MSZ EN 50085 – what will be valid from 2004.

The following accessories of ISONAL 2000® cable trunking system give a good construction possibility to the MSZ EN 50085 type of CTS system, which is with opening cover and can be assembled on the wall or the ceiling.

Quality assurances:

Certificate of type testing: MEEI D1280 K 109 / CCA/HU 0088
Production: MSZ EN ISO 9001:2000 Certificate: 08/100/9517/6

Size and collection of profiles:

 

Nominated size of trunking (width x height) (mm)

Description of profiles

18x9

16x16

25x16

40x16

40x25

50x25

Internal bend

 

X

X

X

X

 

External bend

 

X

X

X

X

 

Flat bend

 

X

X

X

X

 

Equal T unit (same size)

 

X

X

X

X

 

End Cap

 

X

X

X

X

 

Equal ceiling T unit

 

25/16

25/25

     

Unequal T unit (different size))

   

25/16

     

Coupler (cover)

 

X

X

     

Coupler

     

X

X

 

Trunking collection:

 

Code

Execution ( L )

2m

3m

Nominated size

A

B

Standard

Self Adhesive

Standard

18x9

18

9

X

X

X

16x16

16

16

X

X

X

15x18

15

18

X

   

25x16

25

16

X

X

X

25x25

25

25

X

   

32x50

32

50

X

   

40x16

40

16

X

 

X

40x25

40

25

X

 

X

50x25

50

25

X

 

X

 

50x50

50

50

X

   
 

50x100

50

100

X

   

Remark: Standard execution can be made with holes on the bottom (Code: L)

Internal Bend:

Nominated size

A

B

C

D

E

Code

16x16

15,8

15,8

19,4

34

10

A1

25x16

25,1

15,8

28,7

41

19

A2

40x16

40,1

15,8

43,7

48

17

A3

40x25

40,1

24,8

43,7

57

17

A4

External bend

Nominated size

A

B

C

D

E

F

G

Code

16x16

15,8

15,8

19,4

42,5

10

24,9

17,6

EA1

25x16

25,1

15,8

28,7

42,5

15

24,9

17,6

EA2

40x16

40,1

15,8

43,7

59

15

32,4

17,6

EA3

40x25

40,1

24,8

43,7

59

15

32,4

26,6

EA4

End cap:

Nominated size

A

B

C

D

E

F

Code

25x16

13,5

25

22

13

16

13

SE2

40x16

28,5

40

37

13

16

13

SE3

40x25

28,5

40

37

22

25

13

SE4

Nominated size

A

B

C

D

Code

16x16

16

16

13

13,4

SE1

Coupler:

Nominated size

A

B

C

D

Code

16x16

16

16

13

13,4

SE1

Coupler (cover)

Nominated size

A

B

C

D

E

Code

16x16

15,8

17,6

19,4

46

12

C1

25x16

25,1

17,6

28,7

50

12

C2

Properties and applicable fields:

Structure elements, network construction:

With the most often applicable 6 trunking sizes and 30 profiles of the MSZ EN 50085 type of CTS system you can establish a network according to requirements.

This system makes possible a cabling and route at your discretion on the wall and ceiling equally.

It is easy to extend an existing network, or to establish embranchments and extensional or plane reversing with the profiles. For the bigger sizes of cable trunking a cable fixing is applicable.

Mechanical properties:

The perfect connection between the well designed bottom and cover and strengthened catches of the profiles make possible an easy assembling and tight fit. The cover from the bottom can be removed only with a tool. The cable trunking system does not include any thinned and broken out parts, it means it has no “vulnerable points”.

Impact resistance is 2 J, what means a safe protection in average mechanical stress.

Electric properties:

The material of all elements of this cable trunking system is the well known rigid PVC with perfect electrical insulation, it has a perfect shock-proof in the compact statement. The system has no part, which could be on voltage at the application, so it does not need be earthed, but it cannot be used as an earthing.

Thermal properties:

The cable trunking system is safely applicable between a temperature of - 5 °C and + 60
The cable trunking elements against flame are typical for PVC, i.e. they do not spread the flame and after removing the ignition flame they will be extinguished. The material of the cable trunking system should be protected from sudden heat load and from permanently radiant heat.

Protection from external impacts:

Protection from external impacts:

Between the cable trunking elements will not be installed any stuffing-box or stuffing to protect the elements from dust, humidity and corrosion impact. The cable trunking cover and the elements are joining together with overlapping, but do not protect from dust (graininess is smaller than 1 mm), water and corrosion impact.
This cable trunking system makes a protection of IP 40

Electromagnetic compatibility:

If the cable trunking system works functionally, the electromagnetic compatibility is passive.

Selection of cable trunking:

Nominated size of cable trunking (mm)

Calculated efficient cross-section (mm2)

Applicable cross-section by 0,6 filling (mm2)

Capacity
(NYM 3x1,5mm2 diameter 10,5) db (x)

18x9

75

45

 

16x16

140

84

1

18x15

183

110

1

25x16

220

132

2

25x25

426

256

3

40x16

410

246

3

40x25

720

432

5

50x25

860

516

6

50x32

1200

720

6

50x50

2064

1238

9

50x100

4214

2528

22

Principle of selection:

The total amount of cable cross-section should be less or equal to the applicable cross-section of cable trunking.

Fixing of cable trunking:

With screwing: application with button-head screw, washer and chock.

Size and number of screws:

Size of cable trunking

Size of screw

Number of screw as metres

18x9, 16x16

Diameter: 3x30

min. 3x1 pc

25x16

Diameter: 4x40

min. 3x1 pc

25x25

Diameter: 4x40

Min. 3x1 pc

40x16, 40x25

Diameter: 4x40

min. 3x2 pc

50x25, 50x32, 50x50, 50x100

Diameter: 4x40

min. 3x2 pc

Fixing set up:

Size of cable trunking

Type of arrangement

18x9, 16x16, 25x16

In a single-row in the middle line of the cable trunking

40x16, 40x25, 50x25

50x32, 50x50, 50x100

In double rank settled symmetrical to the middle line of the cable trunking, spacing 20mm

Setting up fixing places at 100 mm from the joining of the cable trunking bottoms and profiles are suggested.

Attention: Only insulated fixing elements are applicable for the walls (supporter) made of conductive material.

Double sided self adhesive tape: Quick fixing for sizes at 18x9, 16x16 and 25x16
Remark: This mode is proposed for solid, dustless, non-scaling walls.

Suggestions for fixing:

  1. Examination of application mode for cable trunking at the given place according to the written properties and applicable circumstances.
  2. Examination of the determinant factors for cable trunking route: construction of the building and walls, location of built-in furniture and networks.
  3. Appointing of the route and embranchments of the cable trunking.
  4. Measuring of the lineal parts of the cable trunking.
  5. Appointing those places where fixing is not applicable: for example water or other built-in cable networks.
  6. Appointing the fixing places for the trunking bottom.
  7. Selection of trunking according to the planned cable sizes. (suggested chapter: Selection of cable trunking)
  8. Definition of profiles for joining, embranchments, reversing according to the table of cable trunking size and profile collection.
  9. Dimension of the trunking bottom
    Cutting mode for plastic profile:
    - with hands: fine teethed saw, for example: metal saw
    -with machine: circular saw: diameter: 250 mm, with 80-108 saw-teeth. Suggested cutting speed: 0.4 - 0.5 m/min for 2800 rotation/min. .
  10. Preparing the fixing holes on the bottom of the cable trunking according to chapter of Cable trunking fixing.
  11. Appointing the fixing holes on the wall (remarking or measuring)
  12. Preparing the fixing holes on the walls and screwing up the bottom of the cable trunking.
  13. Dimension of the cover in accordance of the catches of profiles
  14. Cabling
  15. Putting together the cover and profiles.

Most important material properties:

Type of material: rigid PVC ( VSZM AS - 04 / 96 ) including stabilizer and sliding and shockproof addition

Application field: Inside of buildings, protection from medium mechanical impact, for extruded and injection moulded profiles

Colour: RAL 9001 – cream white, RAL 9010 – clear white

Mechanical properties:

Tensile strength:

min. 38 N/ mm2

VSZM - V 001/1996

Elongation at break:

min. 25 %

VSZM - V 001/1996

Impact-bending strength:

 

MSZ 7751

Charpy feathered:

23 °C :min. 10 KJ /m2

 
 

0 °C :min. 6 KJ /m2

 

Thermal properties:

  • Ignitability: hardly inflammable according to VO UL 94
  • it does not spread the flame, after removing the ignition flame it will be extinguished.
  • Vicat softening point MSZ ISO 306 (at 5 kg weight) min 80 °C
  • Linear expansion factor : ~ 7 x 10-6 1/°C
    (it means 1,4 mm modification in length at 20 °C temperature modification)
  • Examination with heater filament 960 °C. MSZ IEC 695

Electrical properties:

  • Spark-resistance: min. 20 KV /mm
  • Surface resistance : min. 1012 ohm
  • Specific volume resistance : min. 1015 ohm/cm
  • Relative dielectric constant : ~ 2,7

Resistance to chemicals: (+) good resistance (o) average resistance (-) no resistance

Acetone

-

Linseed oil

+

Drinks with alcohol

+

Nitrobenzene

-

Ammonia

+

Vegetable oil

+

Mineral oil

-

Rock-tar

+

Petrol

-

Hydrochloric acid ( 30% )

+

Citric acid

+

Salting liquid

+

Glycerine

+

Soup solution

+

Iodine

-

Milk

+

Sulphuric acid ( 50% )

+

Turpentine

+

Sulphuric acid ( 80% )

-

Water

+

For materials not listed here, please ask for the manufacturer reference.

Types of cable trunking (according to the information of MSZ EN 50085):

Types of CTS for construction to walls and ceiling.

Marked numbers on the picture

Types

Content

Construction

1,7,11,12,13

CTS

Insulated conductors, wires and cables

Onto the surface of wall and ceiling, constructed on the wall horizontal or vertical, hung up to the ceiling

5

CTS

Insulated conductors, wires and cables, and instruments (switch, connector, breaker, etc.)

Onto the surface of wall and ceiling, constructed on the wall horizontal or vertical

3,9

CTS

Insulated conductors, wires and cables

Into the surface of wall and ceiling, recessed in the wall horizontal or vertical

Not marked

CTS

Insulated conductors, wires and cables, and instruments (switch, connector, breaker, etc.)

Into the surface of wall and ceiling, recessed in the wall horizontal or vertical

6,15

Floor border CTS

Insulated conductors, wires and cables

Onto the surface of wall

Not marked

Floor border CTS

Insulated conductors, wires and cables, and instruments (switch, connector, breaker, etc.)

Onto the surface of wall

Read more...

Supporting insulators with a nominal working voltage over 1kV

Types: ETA 12, ETB 12, ETC 12, ETB 24-1, ETB 24-2, ETB 40, ETC 40

Standard: MSZ IEC 273, MSZ EN 60 660, VSZM TS 51-86

Application field: For indoor or outdoor application at nominal voltage range above 1 kV

Material: Epoxy casting resin filled with silica flour (for indoor application)

Colour: red (for indoor application)

According to requirements we can produce insulators made of cyclo-alyphatic epoxy casting resin system for outdoor application as well. Insulators for outdoor use are unpainted or they can be coloured according to agreements.

Dimensions and shaping: for example: ETB 12

Execution: In carton

Typical technical data (Description)

 

ETA 12-1

ETA 12-2

ETB 12-1

ETB 12-2

Product number

-

MÖ 2801

MÖ 2801/a

MÖ 3428

MÖ 3428/a

Nominal voltage

kV

12

12

12

12

Test voltage at industrial frequency

kV/1'

28

28

28

28

Impulse test voltage

kV

75

75

75

75

Nominal leaking path*

mm

200

200

200

200

Minimum bending crumbling force at 20 °C

N

3750

3750

7500

7500

Dimension:

diameter of the bottom

mm

70

70

84

84

diameter of the head-piece

mm

56

56

70

70

Height

mm

130

130

130

130

Number of ribs

db

3

3

3

3

Size of the metal cast inserted into the bottom

 

M 16

M 16

M 20

M 20

Size of the metal cast inserted into the head

 

M10

M6

M16

M10

Number of the metal cast inserted into the head

db

1

2

1

2

Nominal mass of the insulators

kg

0,6

0,6

0,95

0,95

Thread start of the metal cast*

mm

12

12

15

15

VEIKI standard inspection report number

-

1064/VBF

1064/VBF

921/VBF

921/VBF

             

Typical technical data (Description)

 

ETC 12-1

ETC 12-2

ETB 24-1

ETB 24-2

Product number

-

ÖF 5593

ÖF 5593/a

MÖ 3476

MÖ 3476/a

Nominal voltage

kV

12

12

24

24

Test voltage at industrial frequency

kV/1'

28

28

50

50

Impulse test voltage

kV

75

75

125

125

Nominal leaking path*

mm

200

200

340

340

Minimum bending crumbling force at 20 °C

N

12500

12500

7500

7500

Dimension:

diameter of the bottom

mm

104

104

92

92

diameter of the head-piece

mm

90

90

70

70

height

mm

130

130

210

210

Number of ribs

db

3

3

7

7

Size of the metal cast inserted into the bottom

 

M20

M20

M20

M20

Size of the metal cast inserted into the head

 

M16

M10

M16

M10

Number of the metal cast inserted into the head

db

1

2

1

2

Nominal mass of the insulators

kg

1,5

1,5

1,6

1,6

Thread start of the metal cast*

mm

10

10

15

15

VEIKI standard inspection report number

-

1041/VBF

1041/VBF

754/VBF

754/VBF

             

Typical technical data (Description)

 

ETB 40,5-1

ETB 40,5-2

ETC 40,5-1

ETC 40,5-2

Product number

-

MÖ 3477

MÖ 3477/a

MÖ 4640

MÖ 4640/a

Nominal voltage

kV

40,5

40,5

40,5

40,5

Test voltage at industrial frequency

kV/1'

80

80

80

80

Impulse test voltage

kV

190

190

190

190

Nominal leaking path*

mm

600

600

600

600

Minimum bending crumbling force at 20 °C

N

7500

7500

12500

12500

Dimension:

diameter of the bottom

mm

107

107

127

127

diameter of the head-piece

mm

70

70

90

90

height

mm

360

360

360

360

Number of the ribs

db

14

14

15

15

Size of the metal cast inserted into the bottom

 

M24

M24

M30

M30

Size of the metal cast inserted into the head

 

M16

M10

M16

M10

Number of the metal cast inserted into the head

db

1

2

1

2

Nominal mass of the insulators

kg

3,3

3,3

5,4

5,4

Thread start of the metal cast*

mm

20

20

20

20

VEIKI standard inspection report number

-

1024/VBF

1024/VBF

1025/VBF

1025/VBF

             

Products have been tested and approved by VEIKI (Hungarian Institute for Research of Electric Power Industry).

Execution: In carton

Read more...

Supporting insulators for nominal working voltage below 1 kV

Types: ET - 500 ETB - 1 ETB - 1/b
Standard: VSZM TS 05.7/2003, VSZM TS 05.8/2003

Application field: For indoor or outdoor application depending on material within nominal voltage range of 0,4-1 kV. 
Material: Epoxy casting resin filled with silica flour – for indoor application
Colour: red – for indoor application

According to requirements we can produce insulators made of cyclo-alyphatic epoxy casting resin system for outdoor application as well. Insulators for outdoor use are unpainted or they can be coloured according to agreements

Sizes and shaping::

 Execution: In carton

Typical technical data (Description)

 

ET-500

ETB-1

ETB-1/b

Product number

-

ÖF 5276

ÖF 5275

ÖF 5921

Nominal voltage

kV

0,5

1,0

1,0

Test voltage for industrial frequency

kV/1'

0,3

10

10

Minimum bending crumbling force on 20 °C

N

3000

7500

7500

Sizes:

diameter of the bottom

mm

35

50

50

diameter of head-piece

mm

35

50

50

maximum diameter

mm

39

55

75

Height

mm

40

50

52

Number of ribs

db

-

-

3

Size of the metal cast inserted into the bottom

-

M8

M12

M12

Size of the metal cast inserted into the head

-

M8

M12

M12

Number of the metal cast inserted into the head-piece

db

1

1

1

Nominal mass of the insulators

kg

0,1

0,26

0,32

Specification of the product

-

VSZM TS 05.7/03

VSZM TS 05.8/03

VSZM TS 505.8/03

         
           

 

Read more...

Crossover insulators 12, 24 kV

Types: ASM 12/8, ASM 12/16, ASM 12/30, ASM 24
Standard: VSZM VSZ 50-86

Application field: At voltage levels of 12 kV, 24 kV for indoor application. It assures the necessary electric insulation for conductors through walls or other structural parts.

Material: Epoxy resin filled with silica-flour – indoor application

According to requirements we can produce crossover insulators made of cyclo-alyphatic epoxy casting resin system for outdoor application as well. Crossover insulators for outdoor application are unpainted or they can be coloured according to agreements

Colour: Indoor application: Red

  Outdoor application: Not painted

Dimensions and shaping:

Typical technical data (Description)

 

ASM 12/8

ASM 12/16

ASM 12/30

ASM 24

Product number

-

ÖF 4276

ÖF 4321

ÖF 4322

ÖF 4323

Nominal voltage

kV

12

12

12

24

Nominal electric current

A

800

1600

3000

1200

Nominal thermic limiting current

kA

20

40

75

30

Nominal thermic limiting time

-

1 sec.

1 sec.

1 sec.

1 sec.

Nominal dynamic limiting current

kA

50

100

187,5

75

Test voltage at industrial frequency

kV/1'

35

35

35

55

Impulse test voltage

kV

75

75

75

125

Sizes:

inner (d/1)

mm

90

110

140

80

enlarged with ribs (d/2)

mm

110

130

160

120

the biggest (d/3)

mm

135

155

185

170

length

mm

272

272

272

490

Sectional sizes/numbers of the contact rails (see the fig. No.4.) can be passed through the armature of the crossover insulator

mm x mm /pc

40x10/1

80x10/1

100x10/2

60x10/1

   

60x10/1

80x10/2

100x10/3

60x10/2

VEIKI standard inspection report number

-

746/VBF

746/VBF

-

748/VBF

             

Products have been tested and approved by VEIKI (Hungarian Institute for Research of Electric Power Industry).

Execution: In cartons

 

Read more...

Connecting insulator

Type: KT – 4 – 125

Standard: VSZM TS 05.3 / 99

Application field: In a network on 24 kV nominal voltage it is used for cable supporting and operating part of column switch section.

Material: Epoxy casting resin filled with silica flour (for outdoor application)

Dimensions and shaping:

According to picture of ÖF 6300

Typical technical data (Description)

 

KT – 4 – 125

Product number

 

ÖF 6300

Nominal voltage

kV

24

Test voltage for industrial frequency

kV/1’

50

Shock voltage - test

kV

125

Nominal long of leakage current

mm

600

Minimal bending crumbling force on 20oC

N

4000

Frame dimensions: bottom part

mm

65

Head part diameter

mm

60

height

mm

270

Number of ribs

db

10

Dimension of threaded cast inserted into the bottom

 

M10

Dimension of threaded cast inserted into the head

 

M8

Number of threaded cast inserted into the head

db

2

Nominal mass of insulator

kg

2,17

Execution: in cartons

 